NOVA X2000 Endverstärker

  

Nova X2000 Endverstärker
Nova X2000 Endverstärker

 

 

Technische Daten

8 ohms per channel (watt):    650

4 ohms per channel (watt): 1.050

2 ohms per channel (watt): 1.500

THD at 1 kHz and 1 dB below clipping: 0.05%

THD at 100 kHz and 1 dB below clipping: 0.06%

THD at 10 kHz and 1 dB below clipping: 0.10%

Hum and noise: 95 dB (1.0 mV)

Channel separation at 10 kHz: 54 dB 

Slew rate: 30 V / µs

Dampingfactor: >500

Input Impedance: 20 k ohms bal. / 10 k ohms bal.

Input Sensitivity: 1.7 V

Frequency Response: 20 Hz - 20 kHz  (20 Hz: -2.5dB  / 20 kHz: -0.5 dB)

Input connectors: Neutrik© XLR female

Link connectors: Neutrik© XLR male

Mode switch: Stereo/brigde/parallel

Limit switch: On / off

Output connectors: Neutrik© SPEAKON©

Soft start: Yes 

Maximum power consumption: 2.500 W

Dimensions unit (mm) W x H x D: 483 x 89 x 400

Weight {net}: 20 kg

 

 

Safety circuits
The comprehensive package of safety circuits protects the connected speakers and periphery in case of trouble. All NOVA X-series amplifiers are equipped with following safety circuits:

► Back EMF protection
Speakers are a complex and reactive load for an amplifier. Because of the high damping factor of all NOVA amplifiers the EMF effect figures not during normal operation. In case of a defective speaker the energy could be sent back to an amplifier. This energy is very high and could destroy parts like transistors of an amplfier without back EMF (Electro-Motive-Force) protection. All NOVA amplifiers are equipped with a back EMF protection and protect from those damages.

► Short circuit protection
A short cicuit in a speaker or cable could destroy the transistors of an amplfier. All NOVA amplifiers are equipped with a short circuit protection. This protects the amplifier from those damages.

► Overheating protection
All NOVA ampifiers are equipped with sensors at the transistors and transformers. Because of permanent monitoring of temperature the built-in fans make sure of sufficient cooling. 

► HF protection
Extremely high frequencies could destroy the voice coils of the connected loudspeakers. All NOVA amplifiers are equipped with HF protection circuits and filters.

► DC protection
DC (direct current) at amplifiers output could destroy the voice coils of connected loudspeakers. All NOVA amplifiers are equipped with DC protection circuits, which avoid DC at the outputs of the amplifiers.

 

 

 

Nova X2000 Endverstärker (vorne links)
Nova X2000 Endverstärker (vorne links)

 

 

 

Nova X2000 Endverstärker (vorne rechts)
Nova X2000 Endverstärker (vorne rechts)

 

 

 

Nova X2000 Endverstärker (hinten)
Nova X2000 Endverstärker (hinten)

 

 

 

Nova X2000 (innen)
Nova X2000 (innen)

 

 

 

Nova X2000 - TPC (Temperatur Protect Circuit)